A Silver coated conductor in an unpresurised area is subject to moisture and has a damaged coating would be likely to cause
- Wet Arc Tracking.
- Silver Migration.
- Red Plague.
Explanation from PART66Online
Red plague is the cuprous-oxide corrosion that attacks silver-plated copper conductor where the silver plating is broken and copper is exposed to moisture, particularly in unpressurised areas. The reddish-brown oxide spreads along the strands and destroys conductivity. Wet arc tracking concerns insulation breakdown and silver migration is a different plating phenomenon, so the damaged-plating-plus-moisture scenario points to red plague.
Mukesh Kumar asked · 1 Aug 2012
plz explain the Question and answer
Community Comments (1)