What is the minimum bend radius of a loom adequately supported at a terminal block?

  • 10 * diameter
  • 8 * diameter
  • 3 * diameter

Explanation from PART66Online

Where a loom is adequately supported close to a terminal block, the cable may be bent to a tighter minimum radius of three times its diameter because the support prevents strain at the bend. Unsupported runs require a larger radius to avoid overstressing the conductors.

J

Jordi asked · 23 May 2020

why is 3*d and not 8*d?

Community Comments (1)

R
Rhysfaulkner96 12 Jun 2026
8x the Diameter is for an unsupported cable, any less then this and you run the risk of flattening the dielectric plates and degrading the centre conductor. however 3x is acceptable when the cable is supported along it's run through out the bend.