A DC generator armature has 6 poles and is lap wound. The number of brushes required are
- 2.
- 3.
- 6.
Explanation from PART66Online
A lap winding has as many parallel paths as poles, and therefore needs one brush set per pole. A six-pole lap-wound machine thus requires six brushes, in contrast to a wave winding which needs only two.
TIAGO TADEU asked · 4 Feb 2022
Please write your question here.
Community Comments (3)
Please Sign In to post a comment.
More discussions in 3. Electrical fundamentals
- Reactive sparking is reduced by
- What is the phase difference in a circuit with 100V, drawing 0.5 amps, consuming 50 Watts?
- A sine wave has 5 amps RMS value. What is the peak value?
- A 10 ohm resistor has a 14.14 V peak drop across it. What power is dissipated?
- If a 1 ohm circuit produces a 50 W output, the phase angle is
- How many amperes will a 28-volt generator be required to supply to a circuit containing five lamps in parallel, three of which have a resistance of 6 ohms each and two of which have a resistance of 5 ohms each?