Paralleling in AC constant frequency is affected by

  • contactors
  • Generator Control Unit (GCU)
  • But Tie Bar (BTB)

Explanation

Paralleling of constant-frequency AC channels is achieved through the bus-tie breakers (bus tie bar), which connect the individual generator busbars together once the generators are synchronised. Contactors and the generator control unit manage individual channels, but it is the bus-tie path that actually links the busbars in parallel.

sasna asking:

I fail to interpret the question...BTB has a different role to play,,,,,???/

Community Comments (3)

J
Jordi Posts: 198 21.04.2021 / 10:45
My original thought was GCU.
A
ANDYSQUIZ Posts: 3 25.06.2022 / 14:49
and mine!
J
Jordi Posts: 198 28.11.2022 / 18:41
it is c indeed because Aircraft Electricity and Electronics (Fifth Edition), Eismin, page 239