Paralleling in AC constant frequency is affected by

  • contactors
  • Generator Control Unit (GCU)
  • But Tie Bar (BTB)

Explanation from PART66Online

Paralleling of constant-frequency AC channels is achieved through the bus-tie breakers (bus tie bar), which connect the individual generator busbars together once the generators are synchronised. Contactors and the generator control unit manage individual channels, but it is the bus-tie path that actually links the busbars in parallel.

S

sasna asked · 27 Aug 2013

I fail to interpret the question...BTB has a different role to play,,,,,???/

Community Comments (3)

J
Jordi 21 Apr 2021
My original thought was GCU.
A
ANDYSQUIZ 25 Jun 2022
and mine!
J
Jordi 28 Nov 2022
it is c indeed because Aircraft Electricity and Electronics (Fifth Edition), Eismin, page 239