The CSD or IDG speed governor setting

  • is not allowed to be adjusted.
  • is adjusted with the engine stationary.
  • is adjusted with the engine running.

Explanation from PART66Online

A constant speed drive (CSD) or integrated drive generator (IDG) holds the generator at constant rpm so it produces a fixed 400 Hz. The speed governor controls output frequency, so its setting is trimmed with the engine running, observing the live frequency, until the correct value is achieved. A static check cannot show the speed actually delivered to the generator.

A

aviaslon asked · 6 Sep 2018

b737 AMM:
E. Adjust the CSD Output Speed
SUBTASK 24-11-11-215-039-001
WARNING: MAKE SURE THE ENGINES ARE STOPPED WHEN YOU ADJUST THE CSD. THE
CSD ADJUSTMENT PUTS MAINTENANCE PERSONS IN THE DANGEROUS ZONE
THAT IS AROUND THE ENGINE INLET. ENGINE SUCTION CAN CAUSE INJURY TO
PERSONS.
(1) Make sure that the engine is stopped (PAGEBLOCK 71-00-00/201)...............

Community Comments (2)

J
Jordi 16 Jul 2021
so this answer is wrong?I also think they should not be runnig.
J
Jordi 17 Jul 2021
this answer is wrong please change it to engine is stationary.