As fuel level increases, system capacitance

  • no change.
  • decreases.
  • increases.

Explanation from PART66Online

Capacitance-type fuel gauges use the fuel as the dielectric between probe plates; fuel has a higher dielectric constant than the air it displaces. As the fuel level rises, more of the probe is immersed and the effective dielectric increases, so the measured capacitance increases with fuel quantity.

H

haridass asked · 12 Sep 2012

i dun gt this point...cn u explain briefly?

Community Comments (1)

P
PART66Online 13 Sep 2012