Specified time of contact between the indentor and test piece in a vickers or brinell hardness test is

  • 20 seconds.
  • 10 seconds.
  • 15 seconds.

Explanation from PART66Online

In the Vickers and Brinell hardness tests the full load is held on the indenter for a specified dwell time, commonly taken as about 15 seconds, so that the material finishes deforming and a stable, repeatable impression is produced before the load is removed and the impression measured. Too short a dwell would give an inconsistent reading.

L

Leehenson asked · 21 Sep 2016

This question is unclear, as contact time is different depending on ferrous or non-ferrous metals.