Specified time of contact between the indentor and test piece in a vickers or brinell hardness test is
- 20 seconds.
- 10 seconds.
- 15 seconds.
Explanation from PART66Online
In the Vickers and Brinell hardness tests the full load is held on the indenter for a specified dwell time, commonly taken as about 15 seconds, so that the material finishes deforming and a stable, repeatable impression is produced before the load is removed and the impression measured. Too short a dwell would give an inconsistent reading.
Leehenson asked · 21 Sep 2016
This question is unclear, as contact time is different depending on ferrous or non-ferrous metals.
Community Comments (0)
No one has posted a comment here yet.
Please Sign In to post a comment.
More discussions in 6. Materials & hardware
- During a Rockwell Hardness test, what dimension is measured?
- The Fatigue limit for steel is generally in the region of, compared to the static U.T.S
- If aluminium alloy is not quenched within the minimum time allowed after heat treatment is it will be
- The colour code on sheet metal indicates
- Kevlar and Nomex are types of
- Which of the following are generally characteristic of aramid fibre (Kevlar) composites?