Specified time of contact between the indentor and test piece in a vickers or brinell hardness test is
- 20 seconds.
- 10 seconds.
- 15 seconds.
Explanation from PART66Online
In the Vickers and Brinell hardness tests the full load is held on the indenter for a specified dwell time, commonly taken as about 15 seconds, so that the material finishes deforming and a stable, repeatable impression is produced before the load is removed and the impression measured. Too short a dwell would give an inconsistent reading.
Leehenson asked · 21 Sep 2016
This question is unclear, as contact time is different depending on ferrous or non-ferrous metals.