To check the structure of a wing
- ultrasound NDT methods are used.
- high voltage X-rays are used.
- low voltage X-rays are used instead.
Explanation from PART66Online
Radiographing a substantial structure such as a wing requires radiation able to penetrate the thickness and varying density of the assembly, which demands high-voltage (high-kV) X-rays. Low-voltage X-rays lack the penetrating power for thick structure, and ultrasonic methods are better suited to specific local checks than imaging a whole built-up structure.
hanozd asked · 22 Jun 2014
low voltage x rays are used
Community Comments (1)