What is the time between the F2 framing pulse and the SPI?

  • 1.45 ms
  • 2 ms
  • 4.35 ms

Explanation from PART66Online

In an SSR reply the Special Position Identification (SPI) pulse follows the last framing pulse F2 by 4.35 microseconds, placing it clearly after the coded reply train. This fixed spacing lets ground equipment recognise the ident pulse; the shorter spacings correspond to positions inside the code train, not the SPI.

S

sasna asked · 3 Sep 2013

if you could explain this

Community Comments (3)

A
avionics 11 Mar 2017
secondary surveillance radar . read this
slideshare.net/yc2levgmail/lesson-ssr
K
kanarele360 9 Nov 2017
Think it should be "us" not "ms"
J
Jordi 9 Apr 2021
not it is ms indeed, not us.