Inwards relief valves usually open at a negative differential pressure not exceeding

  • 0.16 p.s.i.
  • 1.2 p.s.i.
  • 0.5 p.s.i.

Explanation from PART66Online

Inward relief (negative-pressure relief) valves protect the structure against the cabin pressure falling below outside pressure, for example in a rapid descent with the cabin already at low pressure. They are set to open at a small negative differential, typically not exceeding about 0.5 psi, so the structure is never highly loaded inward.

S

simontay asked · 14 Jun 2012

I thought it should be 0.5 psi

Community Comments (4)

E
Edigno92 30 Jun 2014
I'm agree with u
M
markino87 30 Jun 2014
right answer is 0.5 psi
W
watzz 2 Jul 2014
0.5psi
-correct
P
PART66Online 2 Jul 2014
Corrected.