A crimped electrical connection is suspected to be high resistance. How would you verify this without disconnecting the circuit?
- Measure the millivolt drop across the connection with a millivolt meter.
- Check the resistance across the connection using an ohmmeter.
- Apply a 250 volt megger test across the crimped terminal.
Explanation from PART66Online
A high-resistance joint is found by passing the normal circuit current and measuring the small voltage (millivolt) drop across the connection while it is live, since a poor crimp drops more volts for the same current. An ohmmeter cannot be used on a live circuit, and a megger high-voltage test is for insulation, not joint resistance.
IonutGabriel asked · 7 Feb 2019
how to measure with an millivolt meter without disconnecting the circuit?!!!
Community Comments (1)
Please Sign In to post a comment.
More discussions in 7. Maintenance practices
- The damping force in a meter
- A thread on a drawing is labeled 1/2-20 UNF - 1B. The thread is
- If there is a positive allowance between the smallest possible hole and the largest possible shaft, the fit is known as
- A fire resistant cable is proof tested by exposure to a standard fire for
- What is the minimum bend radius of a loom adequately supported at a terminal block?
- A Silver coated conductor in an unpresurised area is subject to moisture and has a damaged coating would be likely to cause