A transformer should always have its
- primary shorted or off load.
- secondary shorted or on load.
- secondary open circuit or on load.
Explanation from PART66Online
A voltage transformer's secondary may be safely left open-circuit (no load) or connected to a load, but it must never be short-circuited, which would draw excessive current. Likewise the primary should not be shorted. Thus the safe states are secondary open-circuit or on load.
chandra.shrestha1988 asked · 27 Feb 2016
Shouldn't it be secondary shorted or on load?
Community Comments (2)
Please Sign In to post a comment.
More discussions in 3. Electrical fundamentals
- Which of the following would be used to calculate a transformer's transformation ratio?
- Which of the following would be used to calculate a transformer's transformation ratio?
- A transformer has 500 turns on the primary and 100 turns on the secondary. The secondary supplies 20V and is connected to a 10 ohm load. The primary current is
- A transformer has 1200 turns primary and 4800 turns secondary. What value of load resistance would be required to give a reflected impedance of 1000 ohms?
- A transformer has 2000V, 500 turns on the primary and 50 turns on the secondary. What would be the line voltage if the transformer were Delta/Star connected?
- In a 4:1 step up transformer, what would give a reflected impedance of 1 kOhm?