Fire detection systems which are routed through another zone

  • must be protected by the use of heat sinks.
  • must be protected from heat sources in the zone.
  • are not allowed.

Explanation from PART66Online

When a detector element or its wiring is routed through a zone it does not monitor, that section must be shielded from local heat sources so the system does not give a false fire warning from heat in the wrong zone. Such routing is permitted provided this protection is fitted, so an outright ban is not correct.

V

vale asked · 22 Jun 2021

Aren't the first and second sentence saying the same thing? Can some one find a reference pls?

Community Comments (0)

No one has posted a comment here yet.