A starter generator has a
- low resistance series field and a low resistance shunt field.
- low resistance series field and a high resistance shunt field.
- high resistance series field and a low resistance shunt field.
Explanation from PART66Online
A starter-generator combines two modes. For starting it acts as a series motor, needing a low-resistance series field to carry the heavy starting current and give high torque. For generating it uses a high-resistance shunt field that draws little current and allows fine voltage regulation. Hence low-resistance series plus high-resistance shunt.
vale asked · 4 Jun 2020
can someone explain pls?
Community Comments (2)
Please Sign In to post a comment.
More discussions in 3. Electrical fundamentals
- An electric motor produces a force of 5 N at a distance of 0.2m from the centre of rotation and rotates at a speed of 100 revs/sec. The motors output is
- Due to armature reaction in a DC motor
- What polarity do interpoles take in a DC generator?
- A 200 volt motor is taking 10 amperes armature current, the armature resistance is 0.1 ohm. The Back- EMF under these conditions will be
- In a an DC motor, the rotation of the MNA
- In a an DC motor, the rotation of the MNA