The inlet of a turbo fan is
- divergent
- convergent
- convergent-divergent
Explanation from PART66Online
A subsonic turbofan intake acts as a divergent diffuser: the duct area increases rearward so incoming air slows and its static pressure rises before reaching the fan, improving compression efficiency. A convergent or convergent-divergent shape would accelerate the flow, which is not wanted at the fan face on a subsonic engine.
rajib asked · 22 Jan 2013
How come?
Community Comments (3)
Check this schematics of CFM56 as example: farm1.static.flickr.com/55/135132177_...
AS you can see, inlet is divergent, but compressor is convergent.
Please Sign In to post a comment.
More discussions in 14. Propulsion
- What is the pressure increase over one stage of a centrifugal compressor?
- The variable bleed valves on a engine at start up is
- in a flow type fuel system, fuel shutoff is done by
- How is fuel flow varied in a variable displacement pressure type pump?
- The fuel metering unit has direct inputs via
- Propeller speed is measured from